Vor
 
 
HI96701C Chlorine Free 0,00 - 5,00 mg/l - Photometer with Cal kit and case
HI96701C Chlorine Free 0,00 - 5,00 mg/l - Photometer with Cal kit and case
THB 21,000.00 * Prices plus VAT plus shipping costs
Star Rating (0)
 
 
Amount:
 
 
 
 

Product information "HI96701C Chlorine Free 0,00 - 5,00 mg/l - Photometer with Cal kit and case"

Chlorine is widely used in making many everyday products, but most notably, it is used for producing safe drinking water the world over. Even the smallest water supplies are now usually chlorinated. It is also extensively used in the production of paper products, dyestuffs, textiles, petroleum products, medicines, antiseptics, insecticides, food, solvents, paints, plastics, and many other consumer products. Most of the chlorine produced is used in the manufacture of chlorinated compounds for sanitation, pulp bleaching, disinfectants, and textile processing.

Organic chemistry demands much from chlorine, both as an oxidizing agent and in substitution, since it often brings many desired properties in an organic compound when substituted for hydrogen, as in one form of synthetic rubber.

The HI 96701 meter measures the free chlorine (Cl2) content in water samples in the 0.00 to 5.00 mg/L (ppm) range.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

 

 

Order Information: HI 96701C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 5.00 mg/L (ppm)
Resolution   0.01 mg/L from 0.00 to 3.50 mg/L;0.10 mg/L above 3.50 mg/L
Accuracy   ±0.03 mg/L ± 3% of reading @ 25°C
Light Source   tungsten lamp
Light Detector   Silicon photocell with narrow band interference filter @ 525nm
Power Supply   9V battery
Auto-off   After 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder.
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.

 

 

More Information about "HI96701C Chlorine Free 0,00 - 5,00 mg/l - Photometer with Cal kit and case"

Other products from HANNA Instruments Inc.
 
 

Available downloads:

Downloads Brochures

Customer evaluation "HI96701C Chlorine Free 0,00 - 5,00 mg/l - Photometer with Cal kit and case"

 
Evaluations will be activated after verification

Write an evaluation

 
 
 
 
 
 
 

The fields marked with * are required.

 
 
 
 
 

Viewed